APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20113 Issued:1981-02-18
Revised:2012-04-19
Style 20113 Multiple-conductor cable using non-integral jacket

Rating60 deg C, 30 Vac, Horizontal Flame.
Insulated ConductorLabeled or complying with manufacturer's AWM procedure.
AssemblyThe assembly consists of a single layer of insulated conductors. A barrier layer, if employed, may be paper, nylon or oriented polyethylene terephthalate.
ShieldOptional - Expanded metallic ground planes with one or both sides. The ground plane may be flat copper or aluminum and may be employed as a solid or mesh construction.
JacketExtruded PVC.
Diameter of core assembly under jacket (inches)Minimum average thickness (mils)Minimum thickness at any point (mils)
2.000 inch or less1512
2.001-4.0003024
4.001-6.0004536
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electronic equipment, in Class 2 or Class 3 circuits.