APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20116 Issued:1981-03-03
Revised:2012-10-24
Style 20116 Multiple-conductor cable using non-integral jacket

Rating80 deg C, 30 Vac, VW-1 flame.
Conductor40-20 AWG, solid or stranded.
InsulationExtruded PVC, XLPVC, PE, XLPE, FRPE, XLFRPE, Foamed PE, Foamed XLPE, Foamed FRPE or Foamed XLFRPE, 5 mils minimum average thickness, 4 mils minimum thickness at any point.
AssemblyTwo to twenty conductors. Twisted singles or groups of twisted insulated singles cabled together lay not specified. Two or three insulated singles or groups of twisted singles may be laid parallel. Fillers and/or barrier layer optional. Optional - singles may employ shield and/or PVC jacket.
ShieldOptional.
JacketExtruded PVC, 5 mils minimum average thickness, 4 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UsePick up lead of video disc or record player in Class 2 circuits where cable is within the enclosure and not subject to abrasion.