APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2012 Issued:1959-05-01
Revised:2012-06-30
Style 2012 Parallel cable with extruded integral insulation and jacket

Rating80 deg C, 300 Vac, FT2 flame, Optional - Oil Resistant 60 deg C or 80 deg C.
Conductor18 AWG - 16 AWG consisting of No. 30 AWG or smaller stranded.
InsulationEtxrduded PVC Integral insulation and jacket, 60 mils min average, 54 mils minimum at any point.
AssemblyTwo conductor, same as SPT-3.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electric refrigerators where exposed to temperatures not exceeding 80 deg C; or Internal wiring of a electric refrigerators where exposed to temperature not exceeding 80 deg C or where exposed to oil at a temperature not exceeding (60 deg C or 80 deg C, whichever is applicable); or Internal wiring of gas or oil-fired domestic heating equipment where exposed to temperature not exceeding 80 deg C, or Internal wiring of gas or oil-fired domestic heating equipment where exposed to temperature not exceeding 80 deg C or where exposed to oil at a temperature not exceeding (60 deg C or 80 deg C, whichever is applicable. Polarity identification may be omitted.

UL and the UL Logo are trademarks of UL LLC © 2024