Rating | 80 deg C, 300 Vac, FT2 flame, Optional - Oil Resistant 60 deg C or 80 deg C. |
|
Conductor | 18 AWG - 16 AWG consisting of No. 30 AWG or smaller stranded. |
|
Insulation | Etxrduded PVC Integral insulation and jacket, 60 mils min average, 54 mils minimum at any point. |
|
Assembly | Two conductor, same as SPT-3. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring of electric refrigerators where exposed to temperatures not exceeding 80 deg C; or Internal wiring of a electric refrigerators where exposed to temperature not exceeding 80 deg C or where exposed to oil at a temperature not exceeding (60 deg C or 80 deg C, whichever is applicable); or Internal wiring of gas or oil-fired domestic heating equipment where exposed to temperature not exceeding 80 deg C, or Internal wiring of gas or oil-fired domestic heating equipment where exposed to temperature not exceeding 80 deg C or where exposed to oil at a temperature not exceeding (60 deg C or 80 deg C, whichever is applicable. Polarity identification may be omitted. |
|