Rating | 60 deg C, 30 Vac, VW-1 flame. |
|
Conductor | 50 AWG minimum. |
|
Insulation | Extruded FRPE or PE or POLYESTER or PVC or XLFRPE or XLPE or XLPolyester or XLPVC, 2 mils minimum average thickness, solid or cellular. |
|
Assembly | Two or more twisted singles or groups of twisted singles twisted together. Lay not specified. Barrier layer and or fillers optional. Two or three conductors and or conductor groups may be laid parallel to form flat cable. Manufacturer shall maintain a complete description of each assembly. |
|
Shield | Optional. |
|
Covering | (Optional) Extruded PVC, Polyamide or Polyester or Lacquered braid. |
|
Jacket | PVC |
| dia of cable under jacket |
| 0.425 inches or less | 30 mils min average | 24 mils minimum at any point |
| 0.426-0.700 dia | 60 avg | 48 min |
| 0.701-1.500 dia | 80 avg | 64 min |
| 1.501-2.500 dia | 110 avg | 88 min |
| 2.501 dia and larger | 140 avg | 112 min |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal or external wiring of class 2 systems of electronic equipment. Cable must be terminated with connector at each end. |
|