APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20126 Issued:1981-04-13
Revised:2012-03-23
Style 20126 Bonded Flat Ribbon Cable

Rating80 deg C, 300 Vac, Horizontal flame.
Conductor36 AWG - 10 AWG solid or stranded round, tinned or bare. May include mixed AWG sizes.
InsulationLabeled or complying with manufacturer's AWM procedure.
AssemblyTwo to 200 insulated singles, twisted pair triads or quads laid parallel in one plane, intermittently or continuously bonded together or bonded to the PVC covering to form a flat ribbon type cable. Manufacturer shall maintain a record of all singles used in each cable. Insulated conductor is built with inner covering (optional), shield (optional), outer covering (optional).
CoveringInner - Optional - One or two sheets of PVC or polyester/PVC laminated film, each sheet is 2 mils minimum thickness at any point, laminated over the cable assembly. Film covering may be perforated. Hole diameter and pattern is not specified.
ShieldOptional.
CoveringOuter - Optional - Extruded PVC 5 mils minimum thickness at any point, 80 mils maximum thickness.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electronic equiupment.