APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20128 Issued:1981-04-13
Revised:2011-12-21
Style 20128 Parallel cable with extruded integral insulation and jacket

Rating90 deg C, 300 Vac, Horizontal flame.
Insulated ConductorNos. 36 AWG - 10 AWG, Labeled or complying with Section 1 of AWM Procedure minimum rating of 90c, 300 V.
AssemblyTwo to 200 insulated singles, twisted pair triads or quads laid parallel in one plane, intermittently or continuously bonded together or bonded to the PVC covering to form a flat ribbon type cable. Manufacturer shall maintain a record of all singles used in each cable.
Covering(Optional)one or two sheets of PVC or polyester/PVC laminated filem, each sheet is 2 mil min at any point, laminated over the cable assembly. Film covering may be perforated. Hole diameter and pattern is not specified.
ShieldOptional
Covering(Optional) PVC, 5 miles min at any point, 80 mils max.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electronic equipment.