APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20131 Issued:1981-04-13
Revised:2011-10-11
Style 20131 Flat ribbon cable

Rating60, 80, 90 or 105 deg C, 30, 150, 300, 600 or 1000 Vac, Horizontal flame.
Conductor36 AWG - 10 AWG solid or stranded.
InsulationLabeled or complying with manufacturer's AWM procedure.
AssemblyTwo to 200 insulated singles, twisted pair triads or quads laid parallel in one plane, intermittently or continuously bonded together or bonded to the PVC covering to form a flat ribbon type cable. Manufacturer shall maintain a record of all singles used in each cable. Insulated conductor is built with inner covering (optional), shield (optional), outer covering (optional).
CoveringOptional. One or two sheets of PVC or polyester/PVC laminated film, each sheet is 2 mil min at any point, laminated over the cable assembly. Film covering may be perforated. Hole diameter and pattern is not specified.
ShieldOptional.
CoveringOptional. Extruded PVC, 5 mils min thickness at any point, 80 mils max thickness.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024