Rating | 80 deg C, 125 Vac, 300 Vac peak, Horizontal flame. |
|
Conductor | 36 AWG - 12 AWG, round or flat, or polyurethane coated copper, 1.5 mils minimum thickness, 6.0 mils maximum thickness. 6 mils minimum width and 100 mils maximum width. |
|
Insulation | Polyester film, 1.5 mils minimum thickness at any point, bonded on each side of conductor, 16 mils minimum width on outside edges of conductors and 16 mils minimum width between adjacent conductors. Length of insulated conductors not specified. |
|
Ground Plane | Ground Plane - Copper foil or mesh, 0.8 mil minimum thickness, 6 mils maximum thickness. On each side of the ground plane 1.5 mils minimum at any point, of polyester. Minimum 16 mils of insulation on outside edges. |
|
Assembly | 2 - 150 conductors. Conductors may be straight or irregular shaped and laid parallel and in one plane. The cable consists of the insulated conductors and ground plane described above, bonded together with a polyester adhesive. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring of electronic equipment. |
|