| Rating | 80 deg C, 50 Vac, VW-1 flame. |
|
| Conductor | 40 AWG - 20 AWG, solid or stranded. |
|
| Insulation | Extruded FRPE, extruded PE, extruded PVC, extruded XLPE, extruded XLPVC, extruded foamed FRPE, extruded foamed PE or extruded foamed XLPE, 5 mils minimum average thickness, 4 mils minimum thickness at any point. |
|
| Assembly | Two to 20 conductors, twisted singles or groups of twisted singles cabled together, lay not specified. Fillers and/or barrier layer optional. |
|
| Shield | Optional. |
|
| Jacket | Extruded PVC, 5 mils minimum average thickness, 4 mils minimum at any point. |
|
| Standard | Appliance Wiring Material UL 758. |
|
| Marking | General. |
|
| Use | Pick up lead of video disc in Class 2 circuits (Less than 15 W where cable is within the enclosure and not subject to abrasion.) |
|