| Rating | 80 deg C, 30 Vac, VW-1 flame. |
|
| Insulation | Labeled or complying with manufacturer's AWM procedure. |
|
| Assembly | Two to twenty insulated singles twisted together. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. Diameter of assembly under jacket one inch maximum. |
|
| Shield | Optional. |
|
| Covering | Optional - A nominal 45 mils PVC covering may be extruded over the conductor assembly. |
|
| Jacket | Extruded PVC, 15 mils min average, 12 mils minimum at any point. |
|
| Standard | Appliance Wiring Material UL 758. |
|
| Marking | General. |
|
| Use | Wiring in Class 2 Circuits of Audio and Video Equipment, or internal wiring of Class 2 Circuits of Electronic Equipment. |
|