APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20144 Issued:1981-07-07
Revised:2012-03-09
Style 20144 Bonded or laminated flat ribbon cable.

Rating80 deg C, 125 Vac, Horizontal flame.
Conductor36 AWG - 16 AWG. May include mixed AWG sizes.
InsulationLabeled or complying with manufacturer's AWM procedure.
AssemblyTwo to 200 insulated singles, twisted pair triads or quads laid parallel in one plane, bonded together or to the PVC covering in such a fashion to form a flat ribbon type cable. Manufacturer shall maintain a record of all singles used in each cable.
CoveringOptional - Two laminated sheets, extruded PVC, 2 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024