APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20145 Issued:1981-07-17
Revised:2012-01-11
Style 20145 Multiple-conductor cable using non-integral jacket

Rating150 deg C, 600 Vac, Horizontal flame.
Conductor24 AWG minimum, resistance wire, solid or stranded.
InsulationExtruded FEP, 10 mils minimum average, 8 mils minimum at any point.
AssemblyTwo or three insulated conductors.
ShieldOptional.
CoveringOptional, braid.
JacketExtruded FEP, 20 mils minimum average, 16 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseHeating cable, where the acceptability of the combination is to be determined by Underwriters Laboratories Inc.

UL and the UL Logo are trademarks of UL LLC © 2024