APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20146 Issued:1981-07-17
Revised:2011-12-30
Style 20146 Multiple-conductor cable using non-integral jacket

Rating200 deg C, 600 Vac, Horizontal flame.
Conductor24 AWG minimum resistance wire.
InsulationFEP, 10 mils min average, 9 mils minimum at any point.
AssemblyTwo to three conductors.
CoveringOptional - Braid and/or shield.
JacketFEP, 20 mils min average, 16 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseHeating cable, where the acceptability of the combination is to be determined by Underwriters Laboratories Inc.

UL and the UL Logo are trademarks of UL LLC © 2024