Rating | 90 deg C, 120 Vac, 240 Vac, 300 Vac, Horizontal flame. |
|
Conductor | 20 AWG - 14 AWG, stranded, copper. |
|
Insulation | Extruded PUR or TPE, 13 mils minimum thickness11 mils minimum thickness at any point. If the optional covering is not employed, the insulation thickness shall be 20 mils minimum average, 18 mils minimum at any point. See Facing Page for compound. |
|
Assembly | Two or three insulated conductors. |
|
Shield | Optional. |
|
Covering | Optional - modified polyurethane, polyester or thermoplastic elastomer, 6 mils minimum at any point. |
|
Jacket | Optional. Extruded ETFE or PUR, 13 mils minimum average thickness, 11 mils minimum thickness at any point. or TPE, 18 mils minimum average, 14 mils minimum at any point. See Facing Page for compound. |
|
Misc. | Conductive Core - Over the conductor is an extruded carbon-loaded (radiation cross-linked) polyolefin, thickness not specified. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Pipe-heating cable where the acceptability of the combination is to be determined by Underwriters Laboratories Inc. |
|