APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20155 Issued:1981-11-13
Revised:2012-03-23
Style 20155 Multiple-Conductor Cable Using Extruded Non-Integral Jacket

Rating105 deg C, 600 Vac, Horizontal flame.
Conductor36 AWG minimum, solid or stranded round, tinned or bare. May use same or mixed AWG size.
InsulationLabeled or complying with manufacturer's AWM procedure.
AssemblyConsists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly.
ShieldOptional. In accordance with the Standard.
CoveringOptional - A 6 mil thick or heavier PVC covering may be extruded over the conductor assembly.
JacketExtruded PVC
Diameter of core assembly under jacket (inches) ¿Minimum average thickness (mils)Minimum thickness at any point (mils)
0.425 inches or less3024
0.425-0.7004536
0.701-1.5006048
major diameter if cable is flat or oval.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electronic equipment or appliances.