Rating | 105 deg C, 600 Vac, Horizontal flame. |
|
Conductor | 36 AWG minimum, solid or stranded round, tinned or bare. May use same or mixed AWG size. |
|
Insulation | Labeled or complying with manufacturer's AWM procedure. |
|
Assembly | Consists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. |
|
Shield | Optional. In accordance with the Standard. |
|
Covering | Optional - A 6 mil thick or heavier PVC covering may be extruded over the conductor assembly. |
|
Jacket | Extruded PVC |
| Diameter of core assembly under jacket (inches) ¿ | Minimum average thickness (mils) | Minimum thickness at any point (mils) |
| 0.425 inches or less | 30 | 24 |
| 0.425-0.700 | 45 | 36 |
| 0.701-1.500 | 60 | 48 |
| major diameter if cable is flat or oval. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring of electronic equipment or appliances. |
|