APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20160 Issued:1982-01-22
Revised:2012-04-23
Style 20160 Multiple-conductor cable using non-integral jacket

Rating80 deg C, 125 Vac, Horizontal flame.
InsulationLabeled or complying with Manufacturer's AWM Procedure.
AssemblyFirst layer: Two-ten insulated singles twisted together with 1.5 inches max length of lay. Binder of nylon lacing cord optional. Second layer (over First layer) Ten-twenty singles cabled around First layer with 1.5 - 2.0 length of lay. Fillers optional. May include PETP binder or barrier.
ShieldOptional.
JacketExtruded PVC. Jacket may be "Tubed" on in lieu of closely fitting jacket.
Diameter of cable under jacket (inches)Minimum average thickness (mils)Minimum thickness at any point (mils)
0.250 or lessNot specified23
0.351-1.000Not specified36
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring or External interconnect of electronic equipment and appliances.

UL and the UL Logo are trademarks of UL LLC © 2024