Rating | 105, 250 Vac, Horizontal flame, Moisture Resistant 75 deg C. |
|
Conductor | 1.75 mils dia resistance wire wound for a min of 25 turns per in on a Rayon, Cotton, Polyester, Fiberglass, Nylon yarn core, Nickel, Copper Alloy or Copper, size varies dependent upon wattage demand. |
|
Insulation | PVC, 45 mils min average, 40 mils minimum at any point. Distance between conductors 7/16 in =/- 1/16 in Web thickness 1/32 in min. Web may have additional rib. See Facing Page for Compound. |
|
Assembly | Two conductors |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | For heat tracing of pipes in industrial or commercial installations only. |
|