APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20167 Issued:1982-03-22
Revised:2019-11-07
Style 20167 Multiple-conductor cable using non-integral jacket

Rating80, 90 or 105 deg C, voltage not specified, Horizontal flame.
Conductor40 AWG min, solid or stranded. May use same or mixed AWG size.
InsulationLabeled or complying with Manufacturer's AWM Procedure
AssemblyConsists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly.
ShieldOptional.
CoveringOptional - A 6 mil or heavier Extruded PVC covering may be extruded over the conductor assembly.
JacketExtruded PVC
dia of cable under jacket
0.350 inches or less20 mils minimum average thickness16 mils minimum thickness at any point
0.351-0.700 dia30 avg24 min
0.701-1.000 dia45 avg30 min
1.001-1.500 dia60 avg40 min
- Major diameter if cable is flat or oval.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring or external interconnection.