APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20170 Issued:1982-03-29
Revised:2017-04-13
Style 20170 Jacketed Cable

Rating60 deg C, 30 Vac, Cable flame.
Conductor40 AWG min., solid or stranded round, tinned or bare copper. May use same or mixed AWG size.
InsulationLabeled or complying with Manufacturer's AWM Procedure.
AssemblyConsists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly.
ShieldOptional.
CoveringOptional- A 6 mil or heavier PVC covering may be extruded over the conductor assembly.
BraidOptional.
JacketPUR, 30 mils min average, 24 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring or external interconnection of electronic equipment

UL and the UL Logo are trademarks of UL LLC © 2024