APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20172 Issued:1982-04-15
Revised:2012-07-16
Style 20172 Multiple conductor cable using non-integral jacket

Rating80 deg C, 30 Vac, Horizontal flame.
Conductor40 AWG - 10 AWG material not specified.
InsulationExtruded FRPE or extruded PE or extuded PVC or extruded XLPE or extruded XLPVC, or extruded foamed FRPE or extruded foamed PE or extuded foamed PVC or extruded foamed XLPE or extruded foamed XLPVC, 2 mils min average, 2 mils minimum 100 mils maximum.
AssemblyTwo to six insulated singles may be twisted or laid parallel to form round, flat or oval cable. Barrier and/or fillers optional.
ShieldOptional.
CoveringOptional - 2 mils minimum of extruded PVC, extruded Polyamide, extruded Polyester, non-extruded Thermoplastic Polyvinylidence Fluoride Resin or extruded Thermoplastic Copolymer or Ethylene and Tetrafluorethylene or non-extruded lacquered braid.
JacketExtruded PVC, 2 mils min average, 40 mils maximum.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Class 2 Circuits in Electronic Equipment.