APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20173 Issued:1982-04-21
Revised:2011-09-27
Style 20173 Multiple-conductor cable using non-integral jacket (Parallel coaxial cable)

Rating80 deg C, 300 Vac, Horizontal Flame.
Conductor30 AWG - 16 AWG, solid or stranded.
InsulationExtruded PE, FRPE, XLPE or XLFRPE, 15 mils minimum average thickness, 13 mils minimum thickness at any point.
AssemblyTwo to six conductors
ShieldOptional.
JacketExtruded PVC, 15 mils minimum average, 12 mils minimum thickness at any point. If rippable construction, the measurements are made after rippling. May employ a web.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electronic equipment.