APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20175 Issued:1982-04-29
Revised:2019-11-07
Style 20175 Multiconductor cable with extruded non-integral jacket.

Rating60 deg C, 30 Vac, Horizontal flame.
InsulationLabeled or complying with Manufacturer's AWM Procedure.
AssemblyConsists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly.
CoveringOptional - A 6 mil or heavier PVC covering may be extruded over the conductor assembly.
ShieldOptional.
JacketCP or NR - NEOPRENE or PVC - extruded
dia of cable under jacket
0.350 inches or less*15 mils min average12 mils minimum at any point
0.351-0.700 dia30 avg24 min
0.701-1.000 dia45 avg36 min
1.001-1.500 dia60 avg48 min
- *Major dia if cable is flat or oval.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electronic equipment in Class 2 wiring systems only.

UL and the UL Logo are trademarks of UL LLC © 2024