Rating | 80 deg C, 150 Vac, Cable flame. |
|
Conductor | 36 AWG - 20 AWG solid or stranded flat or round copper. |
|
Insulation | PE, 7 mils min average, 7 mils min at any point. Top and bottom of cable may form ridges. |
|
Assembly | One or more layers of the flat cable with 20 mils min space between conductors, or flat cables complying with Sec. 2 of the Manufacturer's AWM Procedure. |
|
Shield | Optional, or expanded metallic ground planes, one or both sides. The ground plane may be flat copper or aluminum and may be employed as a solid or mesh constructions. |
|
Covering | Optional. |
|
Jacket | Extruded PVC |
| Diameter of cable under jacket |
| 2.500 inches or less | 30 mils min average | 24 mils minimum at any point |
| 2.501-3.500 dia | 45 avg | 36 min |
| Four or more cables | 24 avg | and 36 min |
| Three or less cables of 3.500 inches or less | 30 avg | 24 min |
| If jacket is laminated the edge width shall be 45 mils min at any point. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | External interconnection of electronic equipment in Class 2 or 3 circuits only. |
|