Rating | 80 deg C, 300 Vac, FT-2 flame. Optional - 60 deg C or 80 deg C Oil |
|
Conductor | 18 AWG - 16 AWG, consisting of No. 30 AWG or smaller strands |
|
Insulation | Extruded PVC, 60 mils minimum average thickness, 54 mils minimum thickness at any point |
|
Assembly | Two conductor, same as SPT-2. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring of electric refrigerators where ripped not more than three inches and where exposed to temperatures not exceeding 80 deg C; or wiring of Butter Conditioners where exposed at the door hinge at a temperature not exceeding 80 deg C. Either marking may also add where applicable dependent upon the compound used: and where exposed to oil at a temperature not exceeding (60 deg C or 80 deg C, whichever is applicable). Polarity identification may be omitted. |
|