Rating | 80 deg C, 150 Vac, Horizontal flame (construction A), Cable flame (constrution B). |
|
Conductor | 32 AWG min., solid or stranded. |
|
Insulation | PE, 10 mils min average, 9 mils minimum at any point. |
|
Assembly | Consists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. The insulation may be applied directly over the conductor or applied as a helically wrapped thread enclosed within a "tubed on" insulation. |
|
Shield | Optional. |
|
Covering | Optional - A 6 mil or heavier PVC covering may be extruded over the conductor assembly. |
|
Jacket | PVC |
| dia of cable under jacket |
| 0.250 inches or less* | (Const A) | 15 mils min average | 12 mils minimum at any point |
| dia of cable under jacket of 0.250 inches or less | (Const B) | 30 avg | 24 min |
| 0.251-0.425 dia | (Const A) and (Const B) | 30 avg | 24 min |
| 0.426-0.700 dia | (Const A) and (Const B) | 45 avg | 36 min |
| *Major dia if cable is flat or oval. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal or External wiring. |
|