Rating | 105 deg C, 300 Vac, Horizontal flame. |
|
Insulation | Extruded PVC, 9 mils minimum average thickness, 7 mils minimum thickness at any point. |
|
Assembly | 2-100 insulated singles or twisted pair or triads laid parallel in one plane, retained by heat or film melt bonded sections at random intervals from 2 to 100 in a part, with or without PVC bands on one side of the cables in between the heat or film melt bonded sections. Width of heat or film melt bonded sections min 1 inch, width of PVC bands, approximately 3/16 (.188) inches. PVC film or polyester/PVC laminated film may be heat bonded on one side of cable. |
|
Shield | Optional. |
|
Covering | Optional - Extruded PVC, 5 mils minimum thickness at any point, 80 mils maximum thickness. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring of electronic equipment, such as computers and electric business machines. |
|