APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20184 Issued:1982-06-23
Revised:2012-03-23
Style 20184 Bonded Extruded Flat Ribbon Cable

Rating105 deg C, 300 Vac, Horizontal flame.
InsulationExtruded PVC, 9 mils minimum average thickness, 7 mils minimum thickness at any point.
Assembly2-100 insulated singles or twisted pair or triads laid parallel in one plane, retained by heat or film melt bonded sections at random intervals from 2 to 100 in a part, with or without PVC bands on one side of the cables in between the heat or film melt bonded sections. Width of heat or film melt bonded sections min 1 inch, width of PVC bands, approximately 3/16 (.188) inches. PVC film or polyester/PVC laminated film may be heat bonded on one side of cable.
ShieldOptional.
CoveringOptional - Extruded PVC, 5 mils minimum thickness at any point, 80 mils maximum thickness.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electronic equipment, such as computers and electric business machines.

UL and the UL Logo are trademarks of UL LLC © 2024