APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20186 Issued:1982-07-14
Revised:2012-04-17
Style 20186 Multiple-Conductor Cable Using Non-Integral Jacket

Rating60 deg C, 300 Vac, Horizontal flame.
Conductor30 AWG minimum solid or stranded.
InsulationExtruded PE, extruded foamed PE, extruded FRPE or extruded foamed FRPE, 30 mils minimum average thickness, 27 mils minimum thickness at any point.
AssemblyTwo conductors in one cord.
ShieldOptional.
JacketExtruded PVC, 24 mils minimum average thickness, 19 mils minimum thickness at any point.
AssemblyOptional - Two or more cords may be cabled together, wrapped with PP tape, shielded and jacketed with PVC, 40 mils minimum thickness, 36 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electronic equipment.