APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20187 Issued:1982-07-13
Revised:2012-04-20
Style 20187 Multi-conductor Cable with Extruded Non-Integral Jacket.

Rating80 deg C, voltage not specified, Cable flame.
Conductor33 AWG - 18 AWG, stranded copper (round or tinsel).
InsulationExtruded Polyester-blend, 7 mils minimum average thickness, 5 mils minimum thickness at any point. See Facing Page for Compound.
AssemblyTwo to ten conductors. May include mixed AWG sizes. Cable may be either straight or wound in retractile form. Core may be either flat or round.
CoveringOptional. Extruded Nylon (Polyamide), 3 mils minimum thickness at any point.
ShieldOptional. Over one or more conductor or groups of conductors.
JacketExtruded Vinyl-Rubber Blend, 25 mils minimum average thickness, 20 mils minimum thickness at any point. See Facing Page for Compound.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseA. "External interconnection of electronic equipment where the overall length does not exceed 5 ft". or B. "External interconnection of electronic equipment where not routed along walls, floors, or other abuse areas".

UL and the UL Logo are trademarks of UL LLC © 2024