Style 20188 Multiple-conductor cable using non-integral jacket

Rating90 deg C, voltage not specified, Cable flame.
ConductorTwo to ten, 18 - 33 AWG tinned or bare, stranded copper (round or tinsel). May include mixed AWG sizes.
InsulationExtruded Polyester. 7 mils min average, 5 mils min at any point. See Facing Page for compound.
ShieldOptional - One or more conductor or groups of conductors may be shielded.
JacketExtruded Vinyl-Rubber blend. 25 mils min average, 21 mils minimum at any point. See Facing Page for compound.
AssemblyCable may be either straight or wound in retractile form. Core may be either flat or round.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseA. "External interconnection of electronic equipment where the overall length does not exceed 5 ft". or B. "External interconnection of electronic equipment where not routed along walls, floors, or other abuse areas".