APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20189 Issued:1982-07-13
Revised:2012-04-26
Style 20189 Single-conductor cable with extruded non-integral jacket.

Rating150 deg C, 600 Vac, Horizontal flame.
Insulated ConductorLabeled Style 2724 with an overall tinned copper or stainless steel braid.
AssemblyThe cable consists of the shielded insulated conductors with the monitor element laid flat and parallel with an overall extruded jacket.
Misc.Monitor Element - Consists of a low temperature melting alloy conductor 35 mils min O.D., with a fiberglass braid, a stainless steel braid and an extruded FEP covering 8 mils minimum at any point.
JacketExtruded FEP, 20 mils minimum average thickness, 16 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UsePipe heating cable where the acceptability of the combination is to be determined by Underwriters Laboratories Inc.

UL and the UL Logo are trademarks of UL LLC © 2024