APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20190 Issued:1982-07-13
Revised:2012-04-24
Style 20190 Jacketed Cable

Rating200 deg C, 600 Vac, Horizontal flame.
InsulationLabeled Style 2712 with an overall tinned copper or stainless steel braid.
AssemblyThe cable consists of the shielded insulated conductors with the monitor element laid flat and parallel with an overall extruded jacket.
JacketFEP, Extruded 20 mils min average, 16 mils minimum at any point.
Misc.Monitor Element - Consists of a low temperature melting alloy conductor 35 mils min O.D., with a fiberglass braid, a stainless steel braid and an extruded fluoronated ethylene propylene covering 8 mils min at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UsePipe heating cable where the acceptability of the combination is to be determined by Underwriters Laboratories Inc.

UL and the UL Logo are trademarks of UL LLC © 2024