Rating | 200 deg C, 600 Vac, Horizontal flame. |
|
Insulation | Labeled Style 2712 with an overall tinned copper or stainless steel braid. |
|
Assembly | The cable consists of the shielded insulated conductors with the monitor element laid flat and parallel with an overall extruded jacket. |
|
Jacket | FEP, Extruded 20 mils min average, 16 mils minimum at any point. |
|
Misc. | Monitor Element - Consists of a low temperature melting alloy conductor 35 mils min O.D., with a fiberglass braid, a stainless steel braid and an extruded fluoronated ethylene propylene covering 8 mils min at any point. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Pipe heating cable where the acceptability of the combination is to be determined by Underwriters Laboratories Inc. |
|