APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20191 Issued:1982-07-23
Revised:2011-10-11
Style 20191 Multiple-conductor cable using non-integral jacket

Rating80 deg C, 30 Vac, VW-1 flame.
InsulationLabeled singles or complying with AWM Manufacturer's Procedure.
AssemblyTwo-forty insulated singles twisted together. Barrier Assemblyand/or fillers optional. Manufacturer shall maintain a complete description of each assembly. Diameter of assembly under jacket one inch maximum.
CoveringOptional - Extruded PVC, 15 mils minimum average thickness, may be extruded over the conductor assembly.
ShieldOptional.
JacketExtruded PVC, 18 mils min average thickness, 15 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseWiring in Class 2 Circuits of Audio and Video Equipment, or Internal Wiring of Class 2 Circuits of Electronic Equipment.

UL and the UL Logo are trademarks of UL LLC © 2024