APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20194 Issued:1982-08-16
Revised:2012-04-16
Style 20194 Multiple-conductor cable using non-integral jacket.

Rating75 deg C, 300 Vac, Horizontal flame.
Conductor19 AWG consisting of two-stranded annealed copper, each 0.75 mm sq diameter. Tinning optional, strand diameter. 0.21 mm maximum.
InsulationExtruded PVC (Cenelec Type TI-2), 0.5 mm minimum average thickness, 0.35 minimum thickness at any point, removable without damage to insulation, conductor, or tinning. Color - one brown, one blue.
AssemblyTwo conductors, Color-one brown, one blue. Singles laid parallel.
JacketExtruded PVC, 0.6 mm minimum average thickness, 0.41 minimum thickness at any point. Does not adhere to singles but fills space between them. Jacket forms oval shape with dimensions 3.2 x 5.2 minimum, 3.9 x 6.4 maximum.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.

UL and the UL Logo are trademarks of UL LLC © 2024