APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20195 Issued:1982-08-16
Revised:2019-01-14
Style 20195 Multiple-conductor cable using non-integral jacket.

Rating75 deg C, 300 / 500 Vac, FT2 flame.
Conductor18-11 AWG, stranded.
InsulationExtruded PVC.
AssemblyTwo to five conductors. Singles twisted together. Lay not specified. Textile fillers optional. Circular cross-section. Colour scheme: 2 Cond - Blue, Brown; 3 Cond - Green/Yellow, Blue, Brown; 4 Cond - Green/Yellow, Blue, Brown, Black; 5 Cond - Green/Yellow, Blue, Brown, Black, Grey.
ShieldOptional, with drain wire.
JacketExtruded PVC.
Number and nominal cross sectional area of conductors (AWG)Minimum average thickness of insulation (mm)Minimum average thickness of jacket (mm)Lower limit of mean overall dimensions (mm)Upper limit of mean overall dimensions (mm)Minimum insulation resistance at 70 deg C (Megohm.km)
2 x 180.60.86.0 or 3.8 x 6.07.6 or 5.2 x 7.60.011
2 x 170.60.86.48.00.010
2 x 150.70.87.49.00.010
2 x 120.81.08.911.00.009
2 x 110.81.110.012.00.007
3 x 180.60.86.48.00.011
3 x 170.60.86.58.40.010
3 x 150.70.98.09.80.010
3 x 130.81.19.612.00.009
3 x 110.81.211.013.00.007
4 x 180.60.86.88.60.011
4 x 170.60.97.69.40.010
4 x 150.71.09.011.00.010
4 x 130.81.110.513.00.009
4 x 110.81.212.014.00.007
5 x 180.60.97.49.60.011
5 x 170.60.98.310.00.010
5 x 150.71.110.012.00.010
5 x 130.81.211.514.00.009
5 x 110.81.413.515.50.007
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal use as Power Supply Cord for Foreign Use Equipment.