Rating | 75 deg C, 300/300 V, FT-2 flame. |
|
Conductor | 22 AWG - 19 AWG, consisting of stranded annealed copper. Tinning optional. For two conductors: a 0.50 sq mm cross section has a 0.21 max strand diameter and a 4.8 - 6.0 mm overall dimention; a 0.75 sq mm cross section has a 0.21 max strand diameter and a 5.2 - 6.4 mm overall dimension; For three conductors: a 0.50 sq mm cross section has a 0.21 max strand diameter and a 5.0 - 6.2 mm; 0.75 sq mm, 0.21 max strand dia, 5.4 - 6.8 mm dim.
|
|
Insulation | Extruded PVC - (Cenelec Type TI-2), Colour scheme: 2 Cond - Light Blue, Brown; 3 Cond - Green/Yellow, Light Blue, Brown; 19 mils minimum average thickness, 17 mils minimum thickness at any point. |
|
Assembly | Two to three singles twisted together. Lay not specified. Textile fillers optional. Circular cross-section. Colourscheme after Jan. 2003: 2 Cond - Blue, Brown; 3 Cond - Green/Yellow, Blue, Brown; Minimum average thickness 0.5 mm, minimum thickness at any point 0.4 mm. |
|
Shield | Optional- with drain wire. |
|
Covering | Optional. |
|
Braid | Optional. |
|
Jacket | Extruded PVC Cenelec Type TM-2, 23 mils min average, 18 mils minimum at any point. May fill spaces but shall not adhere to conductors. Minimum average thickness 0.6 mm, minimum thickness at any point 4.8 mm. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | External use as Power Supply Cord for Foreign Use Equipment. |
|