APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20197 Issued:1982-08-27
Revised:2011-09-29
Style 20197 Multiconductor Cable with Extruded Non-Integral Jacket.

Rating60 deg C, 30 Vac, Cable flame.
Conductor36 AWG - 16 AWG, solid or stranded round.
InsulationExtruded PP, 3.5 - 30 mils thickness to Labeled or complies with manufacturer's AWM Procedure.
AssemblyTwo - 50 individual conductors, different conductor size may be used in one cord. Cable may be either straight or wound in retractile form. Core may be either flat (max 20 conductors) or round. Barrier layer and/or fillers optional.
ShieldOptional.
JacketExtruded TPU
Dia of cable under jacket in inchesMinimum average thickness in milsMinimum thickness at any point in mils
0.425 or less3024
0.426 - 0.7004536
0.701 - 1.5006048
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring or external interconnection of appliances or electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024