Rating | 60 deg C, 300 Vac, FT-2 flame. |
|
Conductor | 18 AWG - 16 AWG consisting of No. 30 AWG or smaller stranded, tinned or bare. |
|
Insulation | Integral with Jacket. Extruded PVC, 60 mils minimum average thickness, 54 mils minimum thickness at any point. |
|
Assembly | Two conductor, same as SPT-2. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring of electric refrigerators where ripped not more than 3 in., or wiring of Butter Conditioners where exposed at the door hinge. Polarity identification may be omitted. |
|