APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2020 Issued:1959-05-01
Revised:2012-03-09
Style 2020 Parallel Cable with Extruded Integral Insulation and Jacket

Rating60 deg C, 300 Vac, FT-2 flame.
Conductor18 AWG - 16 AWG consisting of No. 30 AWG or smaller stranded, tinned or bare.
InsulationIntegral with Jacket. Extruded PVC, 60 mils minimum average thickness, 54 mils minimum thickness at any point.
AssemblyTwo conductor, same as SPT-2.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electric refrigerators where ripped not more than 3 in., or wiring of Butter Conditioners where exposed at the door hinge. Polarity identification may be omitted.

UL and the UL Logo are trademarks of UL LLC © 2024