APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20200 Issued:1982-11-18
Revised:2012-05-21
Style 20200 Multiple-Conductor Cable using Non-Integral Extruded Jacket

Rating60 deg C, 300 Vac, Cable Flame.
InsulationLabeled or complying with Manufacturer's AWM Procedure.
AssemblyTwo or more singles, twisted pairs of groups of twisted singles twisted together or singles or groups of singles may be laid parallel to form flat, oval or round cable. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. May use mixed AWG size.
ShieldOptional.
CoveringOptional - A 6 mil or heavier Extruded PVC covering may be extruded over the conductor assembly.
JacketExtruded PVC
diameter of jacket in inches*mils minimum averagemils minimum at any point
0.700 or less3024
0.701-1.0004536
1.001-1.5006048
1.501-2.5008064
2.501-4.00011088
4.001 and larger140112
*Major dia if cable is flat or oval.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal Interconnection or Internal Wiring.