APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2021 Issued:1959-05-01
Revised:2012-02-29
Style 2021 Parallel Cable with Extruded Integral Insulation.

Rating80 deg C, 300 Vac, FT2 flame. Optional - 60 or 80 deg C Oil.
Conductor18 or 16 AWG stranded, consisting of No. 30 AWG or smaller strands.
InsulationExtruded PVC, 60 mils minimum average thickness, 54 mils minimum thickness at any point.
AssemblyThree conductors similar as Type SPT-2.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of electric refrigerators where ripped not more than three inches and where exposed to temperatures not exceeding 80 deg C; or Wiring of Butter Conditioners where exposed at the door hinge at a temperature not exceeding 80 deg C. Polarity identification may be omitted.

UL and the UL Logo are trademarks of UL LLC © 2024