APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20210 Issued:1982-10-06
Revised:2012-07-24
Style 20210 Multiple-conductor cable using non-integral jacket

Rating125 deg C, 300 Vac.
Conductor12, 14, 16 or 18 AWG, stranded.
InsulationExtruded TPE, See facing page with the following (pin gauge) min dimensions: Average wall thickness 30 mils, Minimum wall thickness 20 mils, Web thickness 45 mils, Wall after rip 13 mils.
AssemblyTwo conductors, The resistance wire is spirally wound around the insulated conductor, having the insulation alternately removed from approx 1/4 in. The AWG size and number of turns per inch will determine the watts per ft of the completed heating cable. The resistance wire is soldered to the exposed bare conductor.
JacketExtruded TPE, 25 mils min average, 20 mils minimum at any point. See facing page for compound.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
Useinternal wiring.