APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20211 Issued:1982-10-06
Revised:2012-07-26
Style 20211 Multiple-conductor cable using non-integral jacket.

Rating125 deg C, 300 Vac, Horizontal flame.
InsulationLabeled Style 20210 with an overall copper or stainless steel braid.
Monitor ElementConsists of a low temperature melting alloy conductor 55 mils min O.D., with a fiberglass braid, a stainless steel braid and an extruded TPE covering, 8 mils min at any point.
AssemblyConsists of the shielded insulated conductors and the monitor element laid flat and parallel with an overall extruded jacket.
JacketExtruded TPE, 25 mils min average. See facing page for compoound.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UsePipe heating cable where the acceptability of the combination is to be determined by UL LLC.

UL and the UL Logo are trademarks of UL LLC © 2024