APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20218 Issued:1982-12-13
Revised:2012-04-26
Style 20218 Multiconductor flat cable with jacket.

Rating105 deg C, 300 Vac, Horizontal flame.
Conductor36 AWG - 20 AWG solid or stranded, tinned or bare copper.
InsulationExtruded PVC, 7 mils minimum thickness at any point, 14 mils minimum insulation between conductors, 100 mils minimum insulation edge width, 500 mils maximum web width.
AssemblyTwo to 150 conductors. Drain wire and/or one or more selected conductors may be in electrical contact with the ground plane.
BraidGround Plane - Copper or expanded copper mesh construction, 3 mils minimum thickness. PETP film or metal faced PETP. film 1 mil minimum thickness, may also be included between ground plane and insulated conductors and/or between ground plane and jacket over ground plane.
JacketPVC film, 10 mils minimum average thickness is extruded over the ground plane assembly.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electronic equipment.