APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2022 Issued:1959-05-01
Revised:2011-12-02
Style 2022 Parallel cable with extruded integral insulation

Rating90 deg C, 300 Vac, FT-2 flame, Oil Resistant 60 deg C or 80 deg C (optional).
ConductorThree No. 18 or 16 AWG consisting of No. 30 AWG or smaller tinned or bare copper strands.
InsulationSame as for Type SPT-2, PVC, 60 mils minimum average thickness, 54 mils minimum at any point.
AssemblyThree conductor, same as SPT-2.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Electric Refrigerators where ripped not more than 3 in and where exposed to temperatures not ex- ceeding 90 deg C; or Wiring of Butter Conditioners where ex- posed at the door hinge at a temperature not exceeding 90 deg C. Either marking may also add where applicable de- pendent upon the compound use; and where exposed to oil at a temperature not exceeding (60 deg C or 80 deg C; whichever is applicable). Polarity identification may be omitted.