Rating | 200 or 250 deg C, 150 Vac, Horizontal flame. |
|
Insulation | Labeled or complying with manufacturer's AWM Procedure. |
|
Assembly | Two or more individually insulated conductors or groups of insulated conductors cabled together. All conductors in any group twisted together. If more than one group is used, groups shall also be twisted together. The length of lay of the twisted conductors or groups is not specified. A barrier layer, if employed, may be a fibrous wrap serving, or braid; paper; nylon (polyamide); oriented polyethylene terephthalate; or thermoplastic-tape wrap. Such a barrier would serve to protect the cable during further processing and would be applied immediately over the twisted assembly of individual conductors or groups of conductors. |
|
Shield | Optional. Shield(s) may be provided over the complete conductor core or over groups of conductors. |
|
Covering | Optional extruded FEP, PTFE or PFA inner covering(s) may be provided over the complete conductor core or over groups of conductors. Thickness not specified. |
|
Jacket | Extruded PFA. |
| dia of cable under jacket |
| 0.425 inches or less | 10 mils minimum average thickness | 8 mils minimum thickness at any point |
| 0.426-0.700 dia | 15 avg | 12 min |
| 0.701-1.500 dia | 20 avg | 16 min |
| 1.501-2.500 dia | 30 avg | 24 min |
| 2.501 dia and larger | 45 avg | 36 min |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring. In addition, the tag may also indicate the following: 300 V peak - For Electronic Use Only. |
|