APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20226 Issued:1982-12-29
Revised:2011-11-07
Style 20226 Multiconductor cable with extruded non-integral jacket.

Rating80 deg C, 30 Vac, Horizontal flame.
Conductor30 AWG - 16 AWG, solid or stranded.
InsulationExtruded XLPE, 8 mils minimum average thickness, 6 mils minimum thickness at any point.
AssemblyTwo or more conductors.
ShieldOptional.
JacketPVC
Diameter of core assembly under jacketMinimum average thicknessMinimum thickness at any point
0.350 inch or less15 mils12 mils
0.351-0.700 inch30 mils23 mils
0.701-1.000 inch45 mils36 mils
1.001-1.500 inch60 mils48 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Class 2 Circuits In Electronic Equipment.

UL and the UL Logo are trademarks of UL LLC © 2024