APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20228 Issued:1983-01-03
Revised:2012-07-26
Style 20228 Laminated flat Cable

Rating105 deg C, 30 Vac, Horizontal flame.
Conductor40 AWG min, material not specified. May include mixed AWG sizes.
InsulationPVC or XLPVC , 6 mils min average, 5 mil min at any point. Min 26 mils between conductors, 15 mils min edge width. Irradiation optional.
AssemblyTwo to 100 uninsulated wires laid parallel in one plane, laminated between 2 sheets of PVC,
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring