APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20229 Issued:1983-07-07
Revised:2023-02-28
Style 20229 Multiple-Conductor Cable using Non-Integral Extruded Jacketed

Rating150 deg C, 300 Vac, Cable Flame, Optional - Oil Resistant 80 deg C.
ConductorSolid or Stranded Round.
InsulationLabeled or complying with manufacturer's AWM Procedure. The designations of all styles of individual conductors used in making up the cable assembly shall be available.
AssemblyTwo or more individually insulated conductors or groups of insulated conductors cabled together. All conductors in any group twisted together. If more than one group is used, groups shall also be twisted together. The length of lay of the twisted conductors or groups is not specified. Optional Fillers may be employed. A barrier layer, if employed, may be a fibrous wrap serving, or braid; paper; nylon; oriented polyethylene terephthalate; or thermoplastic-tape wrap. Such a barrier would serve to protect the cable during further processing and would be applied immediately over the twisted assembly of individual conductors or groups of conductors.
ShieldOptional.
JacketExtruded FEP
diameter of cable under jacket in inchesmils minimum averagemils minimum at any point
0.425 or less2520
0.426-0.7003024
0.701-1.5004536
1.501-2.5006048
2.501 and larger8064
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal Interconnection or Internal Wiring.