Rating | 150 deg C, voltage not assigned, Cable Flame, Optional - 80 deg C Oil Resistant. |
|
Insulated Conductor | Labeled or complying with manufacturer's AWM procedure. The designations of all style wires used in making the cable assembly shall be available. |
|
Assembly | Two or more individually insulated conductors or groups of insulated conductors cabled together. All insulated conductors in any group twisted together. If more than one group is used, groups shall also be twisted together. The length of lay of the twisted insulated conductors or groups is not specified. Optional fillers may be provided. A barrier layer, if employed, may be a fibrous wrap serving, or braid; paper; nylon; oriented polyethylene terephthalate; or thermoplastic-tape wrap. Such a barrier would serve to protect the cable during further processing and would be applied immediately over the twisted assembly of individual conductors or groups of insulated conductors. |
|
Shield | Optional. |
|
Jacket | Extruded FEP. |
| Diameter of core assembly under jacket | Minimum average thickness | Minimum thickness at any point |
| 0.425 inch or less | 25 mils | 20 mils |
| 0.426 - 0.700 inch | 30 mils | 24 mils |
| 0.701 - 1.500 inch | 45 mils | 36 mils |
| 1.501 - 2.500 inches | 60 mils | 48 mils |
| 2.501 inches or greater | 80 mils | 64 mils |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring or external interconnection of appliances or electronic equipment. |
|