APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20234 Issued:1983-10-31
Revised:2018-03-16
Style 20234 Multiple-conductor cable using non-integral jacket

Rating80 deg C, 600, 1000 Vac, Cable flame.
Insulated ConductorLabeled or complying with manufacturer's AWM Procedure.
AssemblyTwo or more individually insulated conductors or groups of insulated conductors cabled together to form a round cable. All conductors in any group twisted together. If more than one group is used, groups shall also be twisted together. The length of lay of the twisted conductors or groups is not specified. A barrier layer, if employed, may be extruded thermoplastic, a fibrous wrap serving, or braid; paper; nylon; oriented polyethylene terephthalate; or thermoplastic-tape wrap. Such a barrier would serve to protect the cable during further processing and would be applied immediately over the twisted assembly of individual conductors or groups of conductors or over the shield, if provided. A flat or oval cable may also be constructed with not more than three rows of single conductors or groups of conductors. Fillers may be provided.
ShieldOptional.
CoveringOptional.
BraidOptional, provided over Jacket.
JacketPUR.
Diameter of core assembly under jacketMinimum averageMinimum at any point
0.700 inch or less45 mils36 mils
0.701-1.000 inch60 mils48 mils
1.001-1.500 inch80 mils64 mils
1.501-2.500 inch110 mils88 mils
2.501 inch and larger140 mils112 mils
*Major dia if cable is flat or oval.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal interconnection of electronic equipment.