Rating | 80 deg C, voltage rating not specified, Cable flame. |
|
Conductor | 36 AWG minimum, Solid or Stranded. |
|
Insulated Conductor | Labeled or complies with manufacturer's AWM Procedure. |
|
Assembly | Two or more individually insulated conductors or groups of insulated conductors cabled together to form a round cable. A flat or oval cable may also be constructed with not more than three rows of single conductors or groups of conductors. The length of lay of the twisted conductors or groups is not specified. Fillers may be used in a cable but are not required. A barrier layer, if employed, may be a fibrous wrap serving, or braid; paper; nylon; oriented polyethylene terephthalate; or thermoplastic-tape wrap. Such a barrier layer would serve to protect the cable during further processing and would be applied immediately over the twisted assembly of individual conductors or groups of conductors or over the shield, if provided. |
|
Covering | Optional. Extruded PVC, 4 mils or heavier wall, or other thermoplastic covering may be extruded over the conductor assembly or groups of conductors (with or without shields). |
|
Shield | Optional. |
|
Jacket | Extruded TPU. |
| Diameter of cable under jacket | Minimum average thickness | Minimum thickness at any point |
| 0.425 inch or less | 45 mils | 36 mils |
| 0.426-0.700 inch | 60 mils | 48 mils |
| 0.701-1.500 inch | 80 mils | 64 mils |
| 1.501-2.500 inch | 110 mils | 88 mils |
| 2.501 inch and larger | 140 mils | 112 mils |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring or external interconnection of electronic equipment. |
|